Check the ARGB connector and the motherboard connector. Please follow the steps bellow or watch the video tutorial Liquid Cooler ARGB No Function
A. Check the ARGB connector
Step 1: Check the ARGB wires are connected
Step 2: Connect the liquid cooler wire to the ARGB controller hub
Step 3: Connect the ARGB controller hub to SATA power connector
B. Check the motherboard connector
Step 1: Check the ARGB wires are connected
Step 2: Connect the liquid cooler wire to the ARGB controller hub
Step 3: Connect the ARGB connector of motherboard
Check the water pump connection to the motherboard or enter BIOS to check. Please follow the steps bellow or watch the video tutorial “Is The Water Pump Functioning Normally”
Step 1: Check the water pump connector on the motherboard
Step 2: Turn on the computer and press function key entering BIOS
Step 3: Enter BIOS and check the CPU fan speed and pump
Watch the video tutorial Liquid Cooler ARGB No Function
Watch the video tutorial Pump function check
Watch the video tutorial Deep dive into the MasterLiquid 360 Atmos
Watch the video tutorial MasterAir MA624 Stealth INTEL and AMD Installation Video
Watch the video tutorial MasterAir MA612 Stealth ARGB Installation Video
Watch the video tutorial MasterAir MA612 Stealth Installation Video
Case
While the computer is running, sequentially unplug the power cables of the case fan, water cooler head, and water cooling fan to identify the source of the noise. Please follow the steps bellow or watch the video tutorial Abnormal Noise
Step 1 : Unplug the power cable of the case fan
Step 2 : Unplug the power cable of the liquid cooler head
Step 3 : Unplug the power cable for the water cooling fan
The three most commonly asked IRIS parameter adjustments are: multiple displays, uploading custom videos, and adjusting case ARGB. Please follow the steps bellow or watch the video tutorial How to Adjust Parameters in MasterPlus - HAF 700 EVO LCD Display (IRIS)
Step 1 Hardware Installation
Step 2 Download and install MasterPlus
Step 3 Perform IRIS display calibration / I. Multi Display
Step 3 Perform IRIS display calibration / II. Upload Custom Video
Note: The video size should be 480x480 pixels or smaller
Step 3 Perform IRIS display calibration / III. Change ARGB
Upgrade the MasterPlus
Watch the video tutorial How to Build Your Next PC with the Qube 500 Case
Watch the video tutorial PC Building with the Qube 500
00 Prepare
STEP 0-1
Download Iris LCD update files from our website.
Continue to Step 01 Install Driver.
01 Install Driver
Continue to Step 02 Prepare for LCD BIOS update.
02 Prepare for LCD BIOS update
1. Find the pin hole.
2. Press for 5 seconds, wat for LCD to go dark.
Continue to Step 03 BIOS update.
03 BIOS update
Finished!! LCD will restart automatically.
Please restart MasterPlus+, after LCD has been restarted.
1. Align the fan to the correct holes as shown below
2. Attach the fan with the standard case fan screws that come with the fan.
Power Supply
Please follow the steps below for troubleshooting or watch the video tutorial PSU No Power
Step 1. Check the AC power cord
Step 2. Check the power switch is on
Step 3. Connect all power connectors
First, You need to prepare your computer hardware specifications previously, and try our free online tool – “power supply calculator”. Please follow the steps bellow or watch the video tutorial How to calculate the wattage you need with online PSU calculator
Prepare your computer hardware specifications previously
And click Builder's Zone > Power Supply Calculator
The minimum power wattage required
The power supply solution we recommended
Find your ideal PSU model!
American Wire Gauge (AWG) is a standard for the width of electrical wire used predominately in North America. The standard specifies the width of the diameter of the wire, ranging from 0000 to 40. The diameter decreases as the wire gauge number get larger.
It is an important factor to evaluate when purchasing a power supply unit because the thicker the cable used the higher the temperature it can endure without problems.
In most cases, current noise is not a huge factor during normal use. This is because it’s usually drowned out by other components and fans spinning. But during idle mode when other components are off, current noise can be noticeable and annoying. This is a really odd situation because it means the power supply is causing a problem that doesn’t really effect normal operation. This problem could be easily remedied by simply shutting down your computer when it’s not in use, but for many that isn’t an acceptable option.
Currently, manufacturers can only try to reduce current noise by way of three main methods:
A. Dip the transformer into the varnish paint longer to glue every microscopic crack to reduce the switching sound when currents pass through it.
B. There are three main electrical pillars inside a transformer and usually the middle one is shorter. The middle of the three main pillars inside a transformer is usually shorter that the other two. Engineers often use glue to fill this gap which does have a noticeable effect in current noise reduction.
C. Adjust the flow of currents by altering primary and secondary copper wire twining.
Brands can demand these processes from manufacturers all they want but ultimately it comes down to the employees in the factory taking the time to do this. While all three methods do have a positive effect on noise reduction, none of them are radical solutions that completely solve the noise problem and thus are often ignored to cut costs and reduce production times.
Accessories
Check the HDMI connection, Power cables and the RAM in order. Please follow the steps bellow or watch the video tutorial No Display
Step 1: Connect the graphics card with HDMI cable
Step 2: Connect the other side of HDMI cable to the monitor
Step 3: Make sure the monitor power cable is connected
Step 4: Remove the RAM (Random Access Memory)
Step 5: Use the eraser wiping the connecting finger
Step 6: Install the RAM
Common reasons for no audio on a monitor include incorrect settings, faulty cables, or hardware issues. Please follow the steps below for troubleshooting or watch the video tutorial Monitor No Audio
Step 1. Play the audio source
Step 2. Ensure the screen audio source is turned on
Step 3. Check if the output cable is connected properly
Step 4. Reset to default settings
Under sufficient keyboard battery power, you can check the keyboard connection, restart or clean the keyboard, and check the keyboard settings. We have also prepared a video Keyboard Keys Malfunction to assist you in troubleshooting the issue step by step.
Step 1. Make sure the keyboard battery level is sufficient
Step 2. Reset the keyboard to default settings
Step 3. Pair the keyboard with the computer again (Bluetooth / Wired / 2.4 GHz)
Check the charging cable for any damage and ensure it is properly connected (it is recommended to use the charging cable included with the product). You can also clean both ends of the connector and restart the keyboard. Please follow the steps below for troubleshooting or watch the video tutorial Keyboard Cannot Charge. We will explain how to check the keyboard's charging status and wireless connection steps.
Step 1. Connect the keyboard to the computer
Step 2. Check the keyboard charging function
Step 3. Switch to wireless mode for use
To record Macros on the fly is simple.
1. Press FN+F11 to start recording Macro
• The C (Cap lock) LED indicator would start flashing
2. Select a Key to record a Macro
• The C (Cap lock) LED indicator would stay on
• The S (Scroll lock) LED indicator would start flashing
3. Start typing to record Macro. For Pro L, each profile can record up to 20 Macros, and each Macro can store up to 200 characters.
• The C (Cap lock) LED indicator would stay on
• The S, G (Scroll lock & Win Lock) LED indicators would both start flashing
4. When done recording, Press FN+PRT SC or FN+SCR LK or FN+PAUSE to select Macro Repeat Mode
• The C (Cap lock) LED indicator would start flashing again
Note: the different repeat mode is Once, Toggle and Cycle respectively.
• Once: Macro executes once per Macro Key press.
• Toggle: Macro executes indefinitely until macro Key is pressed, and will resume running as Macro Key is pressed again.
• Cycle: Macro executes as long as the Macro Key is pressed.
5. Press FN+ESC to Save and Exit
To delete Macros is also easy.
1. Press FN+F12
2. Select all the keys you wish to have Macro deleted.
3. Press FN+ESC to Save and Exit
To reset all keys back to default
Press FN+E for 5 sec, or until C, S, G LED indicators all flash 4 times to reset all keys and remove all Macros stored.
MasterKeys Pro S/M/L – Quick Macro Recording Guide
To record Macros on the fly is simple.
1. For Models with Profiles, a Profile must be selected first (P1, P2, P3, or P4 for Pro L; FN+1, 2, 3 or 4 for Pro M/S).
2. Press FN+F11 to start recording Macro
3. Select a Key to record a Macro
For PRO LED WHITE, Keys available for recording are lit up, after Key press; selected key would light up brightly.
Keys that already have a Macro recorded would light up brightly; you can still select a key that has a Macro already recorded to overwrite its Macro.
For Pro RGB: Keys available for recording are BLUE; Keys already have macro recorded are RED. You can still select a key that has a Macro already recorded to overwrite its Macro.
4. Start typing to record Macro. For Pro L, each profile can record up to 20 Macros, and each Macro can store up to 200 characters.
5. When done recording, Press FN+PRT SC or FN+SCR LK or FN+PAUSE to select Macro Repeat Mode.
Note: the different repeat mode is Once, Toggle and Cycle respectively.
Once: Macro executes once per Macro Key press.
Toggle: Macro executes indefinitely until macro Key is pressed, and will resume running as Macro Key is pressed again.
Cycle: Macro executes as long as the Macro Key is pressed.
6. Press FN+ESC to Save and Exit (no visual confirmation if the recording is successful).
7. To activate the Macro you have just recorded, just press the Key where you have recorded it.
To delete Macros is also easy.
1. Select Profile (P1, P2, P3, or P4 for Pro L, FN+1, 2, 3 or 4 for Pro M/S).
2. Press FN+F12
3. Select all the keys you wish to have Macro deleted.
For PRO LED WHITE, Keys that already have a Macro recorded would light up faintly.
For Pro RGB: Keys already have macro recorded are RED.
4. Press FN+ESC to Save and Exit1
Remove the switches that are not actuating following Step 2 and straighten out the pins using pliers.
Once they are straight, you can attempt to reinstall the switch.
STEP 1
REMOVE THE KEYCAPS WITH A KEYCAP PULLER
Do not pull forcibly, but gently wiggle side to side and slowly pull up using the keycap puller.
STEP 2
REMOVE THE SWITCHES WITH THE SWITCH PULLER
Hook the top and bottom of the switch at the base and squeeze the switch puller until the two plastic tabs on the side of the switch compress.
Gently pull and wiggle until it comes loose.
STEP 3
GENTLY PRESS NEW SWITCHES INTO PCB
Line up the switch pins with the sockets on the keyboard and gently press until the switch is secured.
STEP 4
PLUG IN THE KEYBOARD AND TEST TO SEE IF THE SWITCHES WORK
Before putting keycaps back on, check using a free online tester. If there are any that do not actuate, the pins may have bent during installation.
If the MM712 lost connection after firmware update, please check the following troubleshooting suggestion:
• Unplug and re-plug dongle to the PC and connect the MM712 under 2.4 GHz mode again.
• Repair the MM712 by the steps found here.
• Double check if the MM712 had been update to the latest version completely.
These steps may resolve the issue, if don’t, please contact us for more help.
If you start the update process and stuck in following windows for a while, please try following instructions to continue the update process.
SITUATION 1
If you are stuck in the window above, you will need to perform the following steps to continue the update.
NOTE: Please DO NOT unplug the dongle during the steps.
STEP 1
Make sure the MM712 is connected in 2.4 GHz mode with dongle plugged in the PC, as well as unplug the USB cable.
STEP 2
Toggle the bottom switch from 2.4 GHz mode to Wired mode.
STEP 3
Toggle back the bottom switch from Wired mode to 2.4 GHz mode.
STEP 4
After switching back to 2.4 GHz mode, MM712 will start to update the MM712 FW automatically.
SITUATION 2
If you have stuck in the MM712 firmware update process for more than 5 minutes, please try following instructions to resolve it.
NOTE: Please make sure to plug the dongle in the PC and the MM712 is connected in 2.4 GHz mode during the steps.
STEP 1
Press “Abort” to exit the update process, or open the “Task manager” and close the task “RENEW”.
STEP 2
Exit MasterPlus+ software first, and reopen the MasterPlus+ software.
STEP 3
It will automatically read the current FW version and pop out the window to tell you to update the FW. Press “Install” to update the firmware again.
STEP 4
Please following the update instructions. After both the MM712 and dongle firmed are updated, the MM712 is ready for normal use.
If it doesn’t, please contact us for more help.
SITUATION 3
If you are stuck on the below window and MM712 lost connection to dongle after finishing dongle firmware update, please try following instructions to continue the MM712 mouse firmware update process.
STEP 1
Press keyboard Enter key to continue to the next process.
STEP 2
Make sure the MM712 is connected in 2.4 GHz mode with dongle plugged in the PC, as well as unplug the USB cable. It will continue to below update window.
STEP 3
Toggle the bottom switch from 2.4 GHz mode to Wired mode.
STEP 4
Toggle back the bottom switch from Wired mode to 2.4 GHz mode.
STEP 5
After switching back to 2.4 GHz mode, MM712 will start to update the MM712 FW automatically.
If you start the update process and the shows “Getting the current firmware version of dongle and MM712, it will take a while” for more than 1 minute, please try following steps to resolve it.
STEP 1
Make sure the MM712 is connected successfully in 2.4 GHz mode. Please make sure the bottom switch of the MM712 had been toggled to 2.4 GHz mode and the MM712 is connected to dongle successfully.
Note: Please make sure MM712 is connected in 2.4 GHz mode, without a USB cable connected to the PC.
STEP 2
Unplug and re-plug in the Dongle to the USB port. This step may resolve the issue.
If it doesn’t, please contact us for more help.
To connect the MasterPlus+ software and update the MM712 FW to the latest version, please toggle the bottom switch to 2.4 GHz mode and make sure the dongle is plugged into the PC.
The MasterPlus+ software will automatically read the current FW version of the MM712 when the MM712 is connected in 2.4 GHz wireless mode, and pop out to tell you to update the FW.
Unfortunately, the MM712 CANNOT update the FW in Wired mode. When open the MasterPlus+ software, it will automatically read the current FW version of the MM712 and pop out the below upgrade instruction.
Please do not close the firmware update window and follow the instructions shown on window to update the firmware again.
STEP 1
Toggle the bottom switch to 2.4 GHz mode
STEP 2
Unplug the USB cable
STEP 3
Plug the dongle into your PC and make sure the MM712 is connected in 2.4 GHz mode.
STEP 4
When the firmware update window pops out, click “OK” or press Enter key to start the update. Please make sure to follow the instructions through the whole updating process.
STEP 5
After both the MM712 and dongle firmware setup is complete, the MM712 is fully updated and ready for normal use.
If you’re having connecting issues listed as below under 2.4 GHz mode, here are some troubleshooting suggestions:
Troubleshooting MM712 connection
• Update to the latest firmware version via MasterPlus+ software. For detailed instruction, please found here.
• Make sure to move the dongle closer to the MM712 and connected directly to the PC.
• Keep other wireless devices away from the MM712 or dongle to avoid RF interference.
• Relocate the Dongle from the back of the PC to a front port for better connection.
• Repair the MM712 by the steps found here.
For more help, please contact us for more help.
Systems
Please follow the steps below or watch the video tutorial System Troubleshooting - Sneaker X
No Power
Ensure that the system is properly connected to a power source. Check the power cable and any power switches.
The system doesn‘t boot
Check if all internal components are securely connected, including the motherboard, RAM, and graphics card.
No display
Verify that the monitor is powered on and connected properly to the graphics card
Test with a different monitor or cable to rule out display issues.
Software
First, download and install the MasterPlus software from the Cooler Master website. If there are any updates for the software or firmware, you will receive automatic notifications upon logging in. For details on connecting the mouse and adjusting parameters, please watch the video MasterPlus Firmware and Light Adjustments
Step 1: Download the Master Plus software
Step 2. Install the MasterPlus software
Step 3. Upgrade the Master Plus software
Step 4. Upgrade the Master Plus firmware
Step 5. 2.4G wireless mode
Click on the device displayed at the top left of the page
Streaming
1. Please download and install the StreamEnjin App on your Android device from the Google Play. Please enable Wifi on your Android Device.
2. Connect the SRC/PGM output monitor, ethernet cable, and power to the StreamEnjin
3. Open the StreamEnjin App. The “Scan QR-Code to connect device” message will be displayed on your Android device.
4. Press and hold the SRC/PGM button on the StreamEnjin to display the QR-Code on your SRC/PGM output monitor.
5. Scan the displayed QR-Code with your Android Device to connect to the StreamEnjin.
6. When connected successfully you will see the “Connected with Device” status on the lower left corner of the app.
1. Download the firmware file onto your USB drive. Connect the USB drive to the USB port on your StreamEnjin.
*USB format must be FAT, FAT32, or exFAT
2. Press the Mute, Pause, and Cut buttons simultaneously.
3. The Mute, Pause, and Cut button lights will turn on when pressed.
4. All lights on the StreamEnjin will display white color LEDs.
5. The Volume LED lights will light up and cycle through in the following sequence to indicate firmware upgrade is in process. Firmware upgrade will take a several minutes.
6. Please wait several minutes for firmware to complete upgrade.
7. The green Volume LED light will begin flashing once firmware upgrade is complete. The StreamEnjin will then reboot.
8. The Scenes lights will cycle through in sequence from 1 to 8
9. Connect your device to the StreamEnjin
10. Go into the StreamEnjin app menu and enter About
11. Check the device information to confirm firmware version. Firmware upgrade is now complete
Watch the video tutorial StreamEnjin - Settings / Tutorial Videos - Ep3
Watch the video tutorial StreamEnjin - Scene Presets / Tutorial Videos - Ep2
Watch the video tutorial StreamEnjin - Scene Presets / Tutorial Videos - Ep1
You can use up to 2 video input sources during your live stream. The scenes can be customized through the scene editor, allowing you to arrange your video layout. The sources can be set in Full-screen, Picture-in-Picture and Picture-by-Picture mode, and each video source can be resized or cropped.
Due to specification limitations, you can only select either input A or B for HDMI 2 as an output source.
The microphone and line in have different sensitivity ratings (mic in: -70db ~ -40db, aux in(line in): -40db ~ 0db). You can adjust the gain for the audio in the StreamEnjin app. Maximum gain setting is 30dB.
Please update the firmware and app to the latest versions. Press and hold AUTO or CUT button for 3 seconds to enable or disable Quick Switch Mode. You can also enable/disable Quick Switch Mode through the app.
Please update the firmware and app to the latest versions. Click on the icon on the bottom right of the PGM preview to resize.
Others
Please follow the steps below and ensure you use the power supply cable that matches your graphics card. For more information, watch the video tutorial Graphics card installation and different types of power cables.
Step 1 Turn off the computer and unplug it from the power source
Step 2 Ensure the graphics card is installed properly and securely locked
Step 3 Insert the power supply cable
Step 4 Make sure the power cable is properly connected to the graphics card
A calibrated ICC color profile is provided with the driver for better color accuracy in Standard Mode in comparison to default value, as a result of low average dE by adjusting LUT (Look-Up Table) values. Please download the Calibrated Color Profile Driver here.
After-sales Service Related Information
In this video, we will indicate the locations of the serial numbers on both the packaging and the products themselves. This will help customers easily find the serial numbers needed for registration, repairs, and other requirements.
How To Find Serial Number of My Cooler Master Product?
Power Supplies
PC Cases
Laptop Cooling Docks
CPU Liquid Coolers
CPU Air Coolers
Case Fans
Sneaker X
Cooling X
Shark X
Monitors
Gaming Chair & Table
Gaming Accessories / Mice
Gaming Accessories / Keyboard
Gaming Headset
ORB X
You can easily reach our customer support team through the Contact Us page on our website.
Fill out the form with your details and let us know how we can assist you.
We are always here to support you and ensure you have a wonderful experience!
You can easily reach our customer support team through the Contact Us page on our website.
Fill out the form with your details and let us know how we can assist you.
We are always here to support you and ensure you have a wonderful experience!
In Europe:
Within the first 2 years after purchase, please return your faulty product to your dealer or reseller for a replacement/refund. If your Cooler Master chassis came with one of our power supplies pre-installed, please return only the failed power supply.
If the product was purchased more than 2 years ago but is still within warranty, please reach our customer support team through the Contact Us page on our website. Fill out the form with your details and let us know how we can assist you.
We are always here to support you and ensure you have a wonderful experience!
Note! Cooler Master will not accept returns without prior approval and a RMA number.
For end users, any product still under warranty should be returned to the original store where you purchased the product and ask for exchange, if there is a defect with your CM product.If you purchased the item online, please reach out to their customer support for assistance.
If the store warranty has expired or the original retailer is no longer in business, please don’t hesitate to contact our customer support team through the Contact Us page on our website. We will then provide the contact information of the distributor who will service the warranty.
If you are in a country with multiple distributors, we kindly ask that you contact our customer support team first, as the distributor who did not import your product may not be able to assist you.
We are always here to support you and ensure you have a wonderful experience!